Abstract

A closed-form analytic current-voltage formula for duct electrostatic precipitators is presented. A short discussion of previous theoretical and numerical solutions is given, followed by an explanation of the theoretical formula derived here. A comparison with experimental data is then given, showing that the present formula is accurate over a wide range of conditions, including wide plate spacing.

Notes

Originally published in IEEE Transactions on Industry Applications, vol.IA-17, no.2, pp.236-239, March 1981. doi: 10.1109/TIA.1981.4503931

Keywords

current-voltage formula, duct electrostatic precipitors

Subject Categories

Electrostatic precipitation

Disciplines

Electrical and Computer Engineering

Publication Date

3-1981

Rights Information

Copyright 1981

Restrictions

Personal use of this material is permitted. Permission from IEEE must be obtained for all other users, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works for resale or redistribution to servers or lists, or reuse of any copyrighted components of this work in other works.

Rights Holder

IEEE

Click button above to open, or right-click to save.

Share